» Nouvelles de l'industrie » What causes a false negative in the nucleic acid test for COVID-19?

Quelles sont les causes d’un faux négatif dans le test d’acide nucléique pour le COVID-19?

2022-03-11

Qu’est-ce qu’un faux négatif COVID-19? Cela signifie que le résultat d'un certain test devrait en réalité être positif., mais le résultat est négatif pour des raisons telles que le fonctionnement, équipement, caractéristiques physiques personnelles, etc.

Des résultats positifs ont été obtenus après des tests négatifs répétés, throat swab samples were negative for multiple tests but finally positive results were detected in respiratory lavage fluid samples, nucleic acid tests were negative but CT imaging screening showed the characteristics of new coronavirus pneumonia.

A sample that should have been positive actually tested negative.

Alors, what causes a false-negative nucleic acid test for COVID-19?

• The problem of low viral load

The impact of sampling period: in the early stage of infection, after the patient gradually recovers, and patients with intermittent detoxification carry a low viral load, which may causefalse negativesin the test.

The influence of sampling site: liquide de lavage broncho-alvéolaire, deep sputum > prélèvement nasal > pharyngeal swab The sampling depth and intensity all affect the viral load.

• Problems with detection reagents

The efficiency and purity of nucleic acid extraction, differences in the sensitivity of in vitro diagnostic reagents, and virus variability.

• Other reasons

The operation is not standardized enough, and the clinical laboratory is not standardized enough.

How to deal withfalse negativesin laboratory tests

1. The patient’s disease course

During different disease stages, the viral load in the patient’s body varies. Par exemple, in the early stage of infection, the patient’s own viral load is low, which may result in a “faux négatif” test.

After the patient gradually recovered, the viral load gradually decreased, and the positive rate of nucleic acid test decreased accordingly. Faced with this situation, it is recommended to carry out multiple nucleic acid tests at different times, conduct regular nucleic acid tests for key populations, and make clinical observations and data summaries.

2. Sampling site

The collection of bronchoalveolar lavage fluid and deep sputum is better than nasopharyngeal swab, and the collection of prélèvement nasal is better than écouvillon oropharyngé. In order to ensure the accuracy of the results, it is recommended to use the nasopharyngeal + oropharyngeal swab method, c'est, to collect nasopharyngeal and oropharyngeal swabs at the same time for testing.

3. Sampling accuracy

The depth and intensity of the sampling should be sufficient. For the collection of nasopharyngeal and oropharyngeal swabs, it is necessary to obtain the deeper epithelial cells in order to detect the presence of the virus.

4. Detection of kit quality differences

There are some differences in the quality of test kits today. With joint efforts and continuous optimization and progress of technology, it will gradually improve. False negatives or false positives caused by reagent problems can be replaced by reagents without batch numbers or manufacturers for comparative testing.

5. Other methods

Suspected cases with a negative nucleic acid test for the new coronavirus can be tested for IgM antibodies as an indicator for supplementary diagnosis. (The new coronavirus IgG antibody test is also used to determine whether you have been infected)

Peut-être que vous aimez aussi

  • À PROPOS DE NOUS


    Société de technologie médicale., Ltée. est un fabricant professionnel de fournitures médicales en Chine, nous produisons et vendons des écouvillons floqués en nylon, Kit VTM, kit de prélèvement salivaire et écouvillon CHG & applicateur.

  • NOUS CONTACTER

    Adresse: Chambre 201, 301 et 401 Bâtiment A n ° 10, Bao long 5ème route, Communauté Tongle, Rue Baolong, District de Longgang,Shenzhen, Guangdong, Chine.

    la toile: www.medicoswab.com

    Numéro de téléphone: +86 0755-28997664

    E-mail: info@medicoswab.com